Directory:Bedini SG:Replications:PES:Sterling Allan:Data:Exp10.4 Different Standing Discharge Rates

From PESWiki

Shortcut URL for this page: http://tinyurl.com/6f8zn

You are here: PES Network (http://pureenergysystems.com) > PESWiki > Directory > Bedini SG > Replications > PES > Sterling D. Allan > Data > Experiment 10.4 Standing Discharge Rates


Exp. 10.4 Different Standing Discharge Rates

Experiment 10.4 from Sterling D. Allan's Replication of John Bedini's "School Girl Radiant Energy Circuit and Motor"


Summary 
Seven Batteries were charged in parallel for several days. When disconnected from the circuit and from each other, their standing discharge rates varied in a consistent pattern. Batteries 1, 2, 3 and 4, which have seen the Bedini SG circuit the longest (off and on since Oct. 9), did not drop nearly as fast at first, but at the end dropped lower in voltage than batteries 5,6,7, which were obtained a couple of weeks after the first four batteries (battery 8 was in input side during charging). This phenomenon is consistent between the first four batteries, and the last three. The graph below takes three representative batteries to illustrate the difference in standing discharge rate over the course of five days.


Graph

Image:Sitting_Discharge_Variations_SDA_Bedini_SG_Exp10p4.gif

I chose batteries 1, 4, and 7 as reflective of general patterns.

All batteries began at 6.96 (in parallel) just prior to the standing discharge experiment. By "standing discharge" I mean there was no load, they were just equilibrating after having been charged quite high (7.63v)

Here is a sampling of data points.

(Batt 3 was headed for another experiment, so it was not measured very closely. Note, also, that Batt. 3 was damaged in Exp. 1. Here it behaves like Batt.s 4-7.)

Disconnected from each other at 20:44.

Date Time Batt.1 Batt.2 Batt.3 Batt.4 Batt.5 Batt.6 Batt.7
Nov13 20:44 6.96 6.96 6.96 6.96 6.96 6.96 6.96
20:45 6.93 6.92 6.95 6.85 6.84 6.81
20:49 6.92 6.91 6.78 6.94 6.81 6.80 6.77
20:52 6.90 6.89 6.74 6.92 6.77 6.78 6.75
21:08 6.85 6.84 6.68 6.88 6.74 6.74 6.71
22:54 6.72 6.71 6.74 6.64 6.64 6.61
Nov. 14 8:25 6.58 6.58 6.59 6.57 6.58 6.57
Nov. 15 1:07 6.54 6.54 6.52 6.55 6.55 6.55
20:30 6.53 6.53 6.51 6.54 6.55 6.54
Nov. 15 1:07 6.54 6.54 6.52 6.55 6.55 6.55
Nov. 18 14:01 6.51 6.51 6.50 6.53 6.54 6.52

Battery 4, which had started out holding so steady relatively, ended up dropping to the lowest end voltage.

Batteries 5 and 6 had mainly just seen solid state resonance charging from the Bedini SG circuit. Battery 7 had not seen the circuit until this Exp. 10 charging (with rotation) episode.

I'm working on a "Battery History" chart that will help make more sense of these difference in performance.

Credits 
Special thanks to Ron Frazier for helping me plot my data using MS Excell.

Materials

  • Both 6V batteries were 6V Panasonic-BSG 4.2Ah/20h sealed lead acid batteries part number LC-R064R2P (http://www.digikey.com/scripts/DkSearch/dksus.dll?PName?Name=P164-ND&Site=US) from Digikey.com.
Data Sheet (http://rocky.digikey.com/WebLib/Panasonic/Web%20data/LC-R064R2P.PDF) | photo (http://rocky.digikey.com/WebLib/Panasonic/Web%20Photos/LC-R064R2P.jpg) | catalogue (http://dkc3.digikey.com/PDF/T043/1292.pdf)
  • Volt Meter by GB Instruments GDT-11, measures to two significant digits to right of decimal.